5_2

Quenching Heat Transfer Experiment

UNICORN

UNIST molten core and coolant interaction experimental facility (UNICORN): Analysis of metallic fuel relocation behavior and debris bed porosity in 19-pin core structure of SFR

hydraulic CRDM
  • Hydraulic control rod drive mechanism (CRDM) for passive in-core cooling system (PINCs)
  • Integrated system (Hydraulic CRDM + Hybrid control rod)
    • Heat removal test – 4-finger control rod assemblies
    • Elevation control – Step-up and down
    • Rod drop test – free drop (600 mm)
heat pipe visualization
  • Heat pipe visualization for understanding the operating mechanism (Heat transfer, operation limits)